Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(1): 89-96, jan.-mar. 2007. graf, tab
Article in English | LILACS | ID: lil-451934

ABSTRACT

The amount of amoxicillin in pharmaceutical formulations was determined using spectra of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), in association with partial least squares (PLS) regression. The spectra of 24 different samples (17 for the calibration set and 7 for the validation set), which had been registered using a Nicolet Magna 550 spectrophotometer, contained 76.7-94.3 percent of amoxicillin in starch. The PLS models were constructed with auto-scaled or variance-scaled data, and multiplicative scatter correction (MSC). The best model presented R²=0.9936, RMSEC=0.441 and RMSEV=0.790. The analytical method proposed is non-destructive and the cost and time of analysis are very much reduced, allowing for the fast and direct determination of amoxicillin content.


Neste trabalho propõe-se a quantificação de amoxicilina em formulações farmacêuticas empregando espectroscopia por refletância difusa no infravermelho com transformada de Fourier (DRIFTS) e regressão por mínimos quadrados parciais (PLS). Foram coletados em um espectrômetro Nicolet Magna 550 os espectros de 24 amostras (17 para o conjunto de calibração e 7 para o conjunto de validação) contendo de 76,7-94,3 por cento de amoxicilina em amido. Para a construção dos modelos PLS foi empregada a correção do espalhamento de luz (MSC) e os dados foram autoescalados ou escalados pela variância. Foi obtido um excelente modelo para a previsão da amoxicilina o qual apresentou R²=0,9936, RMSEC=0,441 e RMSEV=0,790. O método proposto além de não destrutivo apresenta baixo tempo de análise e baixo custo podendo ser facilmente empregado no controle de qualidade das indústrias farmacêuticas.


Subject(s)
Amoxicillin/analysis , Pharmaceutical Preparations , Spectroscopy, Fourier Transform Infrared/methods , Quality Control
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 41(4): 499-505, out.-dez. 2005. graf
Article in Portuguese | LILACS | ID: lil-433328

ABSTRACT

A identificação de diferentes formulações de medicamentos manipulados contendo piroxicam foi estudada, empregando epectros de reflexão difusa no infravermelho médio com transformada de Fourier (DRIFTS), em associação com a técnica de análise por agrupamentos hierárquicos (AAH). Os espectros de amostras, de 5 diferentes farmácias de manipulação, contendo piroxicam (10 mg e 20 mg) e seus respectivos excipientes, foram adquiridos em um espectrofotômetro NICOLET Magna 550, obtendo-se duas réplicas de cada amostra. Para a análise multivariada, as informações espectrais foram tratadas no programa Pirouette® 2.7 da Infometrix, utilizando-se as regiões espectrais...


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal , Drugs, Generic/analysis , Drugs, Generic/therapeutic use , Piroxicam , Similar , Multivariate Analysis , Quality of Homeopathic Remedies , Spectroscopy, Fourier Transform Infrared
3.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 40(3): 387-396, jul.-set. 2004. ilus, graf
Article in Portuguese | LILACS | ID: lil-420687

ABSTRACT

Neste trabalho a identificação e a discriminação de dois diferentes fármacos utilizados como antidepressivos foi estudada, empregando os espectros de reflexão difusa no infravermelho médio com transformada de Fourier (DRIFTS), juntamente com a análise de componentes principais (PCA) e o método de classificação SIMCA. Os espectros no infravermelho de amostras contendo diferentes concentrações dos princípios ativos cloridrato de amitriptilina e cloridrato de imipramina, foram coletados em um espectrofotômetro NICOLET Magna 550, sendo realizadas 2 réplicas para cada amostra, com resolução de 4 cm¯¹ e 32 varreduras. A análise de componentes principais confirmou a existência de dois grupos distintos, correspondendo aos dois diferentes princípios ativos utilizados, além de evidenciar a presença de amostras anômalas no conjunto de dados que, possivelmente, iriam interferir na modelagem...


Subject(s)
Antidepressive Agents , Quality Control , Spectroscopy, Fourier Transform Infrared
SELECTION OF CITATIONS
SEARCH DETAIL